CEILING SUPPORT

Ceiling supported systems are available for

diameters 10”-16".

1. Place Appliance: Position the appliance

according to the manufacturer’s instructions.

The flue outlet collar should be placed

between the rafters or joists above, if possible.

2. Frame Support Opening: Drop a plumb

bob to the center of the appliance’s flue outlet

and mark this center point on the ceiling. Refer

to Table 2 for specific framing and clearance

dimensions. Mark appropriate cutting lines

around the center point. Cut a square hole in

the ceiling for the Support Box. Frame a level,

square opening centered over the hole which

you have cut. (Figures 3 and 4).

Figure 3

Figure 4

MINIMUM OF 3

INCHES BELOW

FINISHED CEILING

CONNECTOR PIPE

GOING TO

APPLIANCE.

ALWAYS MAINTAIN A

MINIMUM OF 18 INCHES

CLEARANCE TO

COMBUSTIBLES FOR

SINGLE-WALL STOVEPIPE

CHIMNEY CAP

STORM COLLAR

ADJUSTABLE

FLASHING

ATTIC

INSULATION

SHIELD

CHIMNEY

SECTIONS

FRAMED

OPENING

ROUND

SUPPORT BOX

ROUND TRIM

COLLAR

JOISTS &

FRAMING

3-INCH MINIMUM

REQUIRED BELOW

FINISHED CEILING