CLEARANCES

Always allow at least a 2-inch clearance

between DuraTech Chimney Pipe and any

combustible materials. Never fill any required

clearance space with insulation or any other

materials. Combustible materials include

lumber, plywood, sheetrock, plaster and lath,

furniture, curtains, electrical wiring and building

insulation. Keep single wall stovepipe at least

18 inches away from combustible materials,

unless a clearance reduction system that is

acceptable to the authority having jurisdiction

is used, or the appliance to be installed is

listed and the instructions specify a different

clearance.

PERMITS

Contact your local Building Official or Fire

Official regarding permits, restrictions, and

installation inspections in your area.

DURATECH CHIMNEY

APPLICATIONS

DuraTech Chimney 1700°F (10”-24” diameter)

is a complete chimney system tested and

listed to UL Test Procedure 103, and ULC

S604. In the United States, DuraTech

Chimney can be used with wood fireplaces,

furnaces, boilers, water heaters, ranges, or

other residential-type appliances fueled by oil,

gas, coal, or wood, that have been tested and

listed for use with a UL103 chimney system.

In Canada, DuraTech can be used with oil &

gas fired appliances listed for use with a Type

A Chimney, in accordance with ULC S604.

DuraTech Chimney 1700°F is available in

10” through 24” diameters. Do not use with

forced draft, positive-pressure appliances.

The DuraTech Chimney system is designed

to extend vertically with a maximum of one

(1) offset (two elbows total) of up to 30° from

vertical. DuraTech Chimney is listed under UL

Re-examination Service Number MH7399.

EQUIPMENT & MATERIALS

Drill / Driver

Hammer

Caulking Gun

Plumb Bob

Screwdrivers (Phillips & Standard)

Tin Snips

Saber or Keyhole Saw

Level

Dependable Ladder

Tape Measure

Proper Gloves and Shoes

Eye Protection

Materials You May Need:

Non-hardening Waterproof Sealant

8 Penny Nails

#8, 2-1/2” & 1-1/2” Wood Screws

Roofing Nails

600OF RTV Silicone Sealant

INSTALLATION NOTES

Proper planning for your DuraTech Chimney

installation will result in greater safety,

efficiency, and convenience, as well as

saving time and money. You must use

only authorized DuraTech Chimney parts

to maintain a listed Chimney system (not

including the connector pipe). Do not mix parts

or try to match with other products, or use

improvised solutions. Do not install damaged

or modified parts. Each solid-fuel appliance

must be vented with its own chimney. Table

1 lists the authorized DuraTech Chimney

components. Practice good workmanship.

Sloppy work could jeopardize your chimney’s

safety. Keep electrical wiring and insulation

away from all chimneys and stovepipes. If you

have any questions, be sure to contact either

your dealer or DuraVent directly.