1. Place Appliance: Position the appliance

according to the manufacturer’s instructions. It

is a good idea to try to position the appliance

so it will allow the chimney to line up centered

between studs.

2. Locate, Cut & Frame Opening:

Determine the location where the chimney will

pass through the wall. The chimney should

pass through the wall, centered between

two studs. The height of the penetration

can be determined by positioning sections

of connector pipe until you have the

desired configuration (refer to the appliance

manufacturer’s installation instructions for

restrictions on connector pipe). Cut and frame

an opening in the inner and outer walls at this

location. Refer to Table 2 for the appropriate

framing dimensions.

3. Install Wall Thimble: The Wall Thimble is a

three piece unit which includes the cover plate,

sleeve extension, and the back portion with

shield. On the outside wall, install the back

portion of the Wall Thimble. Center the back

portion of the Wall Thimble (with shield inside

wall) in the framed opening of the outside wall.

Be sure to seal the flange of the Wall Thimble

around the wall by using a non-hardening

waterproof sealant. Attach the back portion

of the Wall Thimble to the outside wall using

at least (4) 8-penny nails or (4) 1-1/2” wood

screws (Fig 20). Depending on the thickness

of your wall, you will need to adjust the shield

extension to insure that you have a continuous

shield throughout the wall penetration.

Adjustments can be made by sliding the

extension in or out of the back portion of the

shield. Verify that the shield extension reaches

the front cover plate when the cover plate is

in position. Do not install cover plate at this

time. When the shield extension is in position,

secure it to the back portion of the shield using

(4) sheet metal screws (Fig 20).

4. Install Tee Support: Install the Tee

Support on the outside wall. Position Tee

Figure 19

UP

TEE BRANCH

(MUST PENETRATE

A MINIMUM OF 6

INCHES INTO

ROOM)

WALL THIMBLE

ASSEMBLY

FINISHING

COLLAR

CHIMNEY

SECTION

CHIMNEY TEE

1/4"X2" LAG

SCREWS (3

REQUIRED)

TEE CAP

RETAINING BAR

BOLTS FOR

RETAINING BAR

TEE CAP