6 acquiring the edid, Acquiring the edid, Figure 6: tp connector – Kramer Electronics TP-146 User Manual
Page 12: Table 5: tp connector pinout, Is defined in, Figure 6, Table 5, 6acquiring the edid, 10 table 5: tp connector pinout

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Acquiring the EDID
10
Table 5: TP Connector Pinout
3 6
78
1 2
5
4
1
4 5 7 8
6
3
2
Figure 6: TP Connector
EIA /TIA 568A
EIA /TIA 568B
PIN
Wire Color
PIN
Wire Color
1
Green/White
1
Orange/White
2
Green
2
Orange
3
Orange/White
3
Green/White
4
Blue
4
Blue
5
Blue/White
5
Blue/White
6
Orange
6
Green
7
Brown/White
7
Brown/White
8
Brown
8
Brown
Pair 1 4 and 5
Pair 1
4 and 5
Pair 2 3 and 6
Pair 2
1 and 2
Pair 3 1 and 2
Pair 3
3 and 6
Pair 4 7 and 8
Pair 4
7 and 8
6
Acquiring the EDID
The TP-145 transmitter can capture the EDID information from a display device.
To load the default EDID:
1. Plug the 12V DC power adapter into the power socket on the TP-145 and
connect the adapter to the mains electricity.
2. With no display device connected to the TP-145, press the EDID CAPTURE button.
3. The EDID STATUS LED flashes rapidly several times and the new EDID is copied.
To capture the EDID information from a display device:
1. Using a short cable
2. Connect power to the display and switch it on.
, connect the XGA INPUT 15-pin HD connector on the
TP-145 to the input XGA connector of the display.
3. Plug the 12V DC power adapter into the power socket on the TP-145 and to
the mains electricity.
4. Press the EDID CAPTURE button.
5. The EDID STATUS LED flashes slowly several times and the EDID is captured.
6. Disconnect the display.
1 For example, Kramer model number C-MGM/MGM-1