beautypg.com

8 default communication parameters, Default communication parameters, 8default communication parameters – Kramer Electronics VS-801USB User Manual

Page 16

background image

VS-801USB - Default Communication Parameters

13

13

8

Default Communication Parameters

RS-232

Protocol

3000 (Default)

2000

Baud Rate:

115,200

9,600

Data Bits:

8

8

Stop Bits:

1

1

Parity:

None

None

Command Format:

ASCII

ASCII

Example (Input 1 to Output 1):

#AV 1>1

0x01, 0x81, 0x81, 0x81

Switching Protocol

P2000 -> P3000

P3000 -> P2000

Command: 0x38, 0x80, 0x83, 0x81

Command:

#P2000

Front Panel: Press and hold DEVICE

SELECT buttons 1 and 3

simultaneously

Front Panel:

Press and hold DEVICE

SELECT buttons 1 and 2

simultaneously

Ethernet

IP Address:

192.168.1.39

Subnet mask:

255.255.255.0

Default gateway:

192.168.1.1

TCP Port #:

5000

UDP Port #:

50000

Maximum UDP Ports: 10
Maximum TCP Ports:

4

Factory Reset

RESET button

To reset the IP settings to the factory reset values, power cycle the device

while holding in the RESET button, located on the rear panel of the unit

Protocol 3000

Use “Factory” command or #Y 0,760,1