Kramer Electronics VS-41HDCP User Manual
Page 36

VS-41HDCP - Kramer Protocol
33
33
All the values in the table are decimal, unless otherwise stated
Instruction Codes for Protocol 2000
Instruction
Definition for Specific Instruction
Notes
#
Description
Input
Output
0
RESET VIDEO
0
0
1
1
SWITCH INPUT
Set equal to video input
which is to be switched
(0 = disconnect)
Set equal to video output
which is to be switched
(0 = to all the outputs)
2
5
REQUEST
STATUS OF A
VIDEO OUTPUT
Set as SETUP #
Equal to output number
whose status is required
4, 3
16
ERROR / BUSY
For invalid / valid input
(i.e. OUTPUT byte = 4
or OUTPUT byte = 5),
this byte is set as the
input #
0 - error
1 - invalid instruction
2 - out of range
3 - machine busy
4 - invalid input
5 - valid input
6 - RX buffer overflow
9, 25
30
LOCK FRONT
PANEL
0 - Panel unlocked
1 - Panel locked
0
2
31
REQUEST
WHETHER PANEL
IS LOCKED
0
0
16
56
CHANGE TO
ASCII
0
Kramer protocol 3000
19
61
IDENTIFY
MACHINE
1 - video machine name
2 - audio machine name
3 - video software
version
4 - audio software
version
0 - Request first 4 digits
1 - Request first suffix
2 - Request second suffix
3 - Request third suffix
10 - Request first prefix
11 - Request second prefix
12 - Request third prefix
13
62
DEFINE MACHINE 1 - number of inputs
2 - number of outputs
3 - number of setups
1 - for video
2 - for audio
14
NOTES on the above table:
NOTE 1 - When the master switcher is reset, (e.g. when it is turned on), the reset code is sent to the PC. If
this code is sent to the switchers, it will reset according to the present power-down settings.
NOTE 2 - These are bidirectional definitions. That is, if the switcher receives the code, it will perform the
instruction; and if the instruction is performed (due to a keystroke operation on the front panel), then these
codes are sent. For example, if the HEX code
01
85
88
83
was sent from the PC, then the switcher (machine 3) will switch input 5 to output 8. If the user switched input 1
to output 7 via the front panel keypad, then the switcher will send HEX codes:
41
81
87
83
to the PC.
i