Kramer Electronics VP-12x8 User Manual
Page 19
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Operating the VP-12x8
16
7.3 Storing/Recalling IN/OUT Configurations
You can store and recall up to 12 input/output configurations using the 12
input buttons
1
, as Figure 7 illustrates:
Figure 7: Storing and Recalling using the Input/Output Buttons
7.3.1
Storing an Input/Output Configuration
To store the current status in memory, do the following:
1. Press the STO button.
The STO button blinks.
2. Press one of the 12 IN buttons (this will be the setup # in which the
current status is stored). If in the Confirm mode, press the blinking TAKE
button to confirm the action.
The memory stores the data at that reference.
7.3.2
Recalling an Input/Output Configuration
To recall an input/output configuration, do the following:
1. Press the RCL button.
The RCL button blinks.
2. Press the appropriate IN button (the button # corresponding to the setup
#). If in the Confirm mode, that setup configuration will blink in the
7-segment Display, together with the RCL button and the TAKE button,
and will only be implemented after pressing the TAKE button.
The memory recalls the stored data from that reference.
Tip: If you cannot remember which of the 12 input/output configurations is
the one that you want, set the
VP-12x8 to the Confirm mode and manually
scan all the input/output configurations until you locate it.
1 You can store/recall eight additional configurations via RS-232