1 connecting the remote step-in switch and led, Connecting the remote step-in switch and led, Figure 4: remote step-in switch and led wiring – Kramer Electronics SID-X2N User Manual
Page 13
SID-X2N - Connecting the SID-X2N
9
9
2. Connect the unbalanced stereo audio source to the AUDIO IN 3.5mm mini
jack.
3. Connect the AUDIO OUT 3.5mm mini jack to the unbalanced, stereo audio
acceptor.
4. Connect the TP OUT RJ-45 connector to a compatible receiver (for
example, the TP-580Rxr).
5. Connect the REMOTE STEP-IN 3-way terminal block to a contact closure
switch and LED (see
5.1).
6. Connect the REMOTE SELECT 3-way terminal block to a momentary
contact closure switch and LEDs (see
7. Connect the LED ANODES 5-way terminal block to the remote input
indicator LEDs (see
).
8. Connect the power adapter to the SID-X2N and to the mains power.
Note: All LED supplies include a current limiting resistor and are designed to work
with any standard LED.
5.1
Connecting the Remote Step-In Switch and LED
You can connect a remote, contact closure step-in switch to take control of the
input of the attached switcher, as well as a remote step-in LED to the REMOTE
STEP-IN terminal block on the rear panel of the SID-X2N.
illustrates the connections from the terminal block to the switch and LED.
Figure 4: Remote Step-In Switch and LED Wiring