beautypg.com

1 connecting the remote step-in switch and led, Connecting the remote step-in switch and led, Figure 4: remote step-in switch and led wiring – Kramer Electronics SID-X2N User Manual

Page 13

background image

SID-X2N - Connecting the SID-X2N

9

9

2. Connect the unbalanced stereo audio source to the AUDIO IN 3.5mm mini

jack.

3. Connect the AUDIO OUT 3.5mm mini jack to the unbalanced, stereo audio

acceptor.

4. Connect the TP OUT RJ-45 connector to a compatible receiver (for

example, the TP-580Rxr).

5. Connect the REMOTE STEP-IN 3-way terminal block to a contact closure

switch and LED (see

Section

5.1).

6. Connect the REMOTE SELECT 3-way terminal block to a momentary

contact closure switch and LEDs (see

Section

5.2

).

7. Connect the LED ANODES 5-way terminal block to the remote input

indicator LEDs (see

Section

5.3

).

8. Connect the power adapter to the SID-X2N and to the mains power.

Note: All LED supplies include a current limiting resistor and are designed to work

with any standard LED.

5.1

Connecting the Remote Step-In Switch and LED

You can connect a remote, contact closure step-in switch to take control of the

input of the attached switcher, as well as a remote step-in LED to the REMOTE

STEP-IN terminal block on the rear panel of the SID-X2N.

Figure 4

illustrates the connections from the terminal block to the switch and LED.

Figure 4: Remote Step-In Switch and LED Wiring