beautypg.com

Kramer Electronics VP-32K User Manual

Page 10

background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Connecting theVP-32K 3x1 PC / Audio Switcher

8

5.2 Controlling via the REMOTE Connector

The contact closure remote control pins operate in a similar way to the input

selector buttons. Using the contact closure remote control lets you route an

input to the outputs by remote control. To do so, temporarily connect the

required input (from 1 to 3) pin on the REMOTE terminal block connector to

the G (ground) pin, as illustrated in the examples in Figure 6. The appropriate

front panel push button illuminates as the selected input routes to both

outputs.

DO NOT connect more than one PIN to the G PIN at the same time and

DO NOT interconnect PIN 1, PIN 2 or PIN 3

Figure 6: Connecting the REMOTE Connector