ConTech Lighting RAN15038 User Manual
Installation instructions
Flexible Conduit
Trim Frame
J-Box
Mounting
Plate
Hex Head
Screws
Housing
RL-KIT #3
Key Hole
Slots
Mounting Stud
Flat Hanger Bar
Narrow Slots
www.con-techlighting.com
1-847-559-5500
ACCENTUATE INST
All specifications subject to change without notice.
IMPORTANT SAFETY INSTRUCTIONS:
• Read all the instructions before installation. Save instructions for later use.
• Turn off power at fuse or circuit breaker box before installation or before doing any maintenance work.
• Product must be grounded to avoid potential electric shock and any other potential hazards. Work on a sturdy, nonconductive ladder.
• Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in compliance with National
Electrical Code and local codes. Use of accessory equipment is not recommended. For indoor use only.
• Installing contrary to instructions may cause unsafe conditions.
• Do not block light from the trim aperture, in whole or in part, as this may cause unsafe conditions. Do not install closer than 6" from any
curtain or similar combustible material.
• Warning: Risk of fire. Most dwellings built before 1985 have supply wire rated at 60°C. Consult a qualified electrician before installation.
• To avoid hazards to children, account for all parts and properly dispose of all packing materials.
• Call the Technical Support department at Con-Tech Lighting with any installation questions: 847.559.5500.
INSTALLATION PROCEDURES
1. Carefully remove packing inserts and slim inner carton containing the
white trim frame.
2. Locate the small plastic bag that contains the Hex Key (tightens the
hex screws that mount the housing to the plaster frame) and Lock-
ing Tool (secures lamp-holder in desired position).
3. Assemble RL-KIT #3:
• Select “L” bracket with the longer base plate. Attach to short end of
mounting plate with J-Box by fitting keyhole slots in bracket over the
setscrews in mounting plate. Adjust to desired length, tighten screws.
Repeat with remaining bracket on opposite end of mounting plate.
• Mount the wing-style brackets to the “L” brackets with the open end
facing out (Fig. 2). Pass mounting stud through bracket slot, secure
with wing nut and washer provided.
• Narrow slots in the bracket accept flat hangerbars (Con-Tech
HB-24), C-shaped openings accept C-Channel hanger bars (Con-Tech
HBC-24). C-shaped openings may also be used for 1/2" conduit.
• Vertical slots in brackets allow a 5-1/2" overall height adjustment.
Desired housing position is for the plaster frame edge to be even
with the finished ceiling, firmly tighten the wing nut.
4. Use Hex Key to make final height adjustments of the housing within
the plaster frame.
DO NOT PLACE ANY INSULATION MATERIAL
WITHIN THREE INCHES OF THE HOUSING.
5. The Accentuate housing is pre-wired. Power must only be brought to
the junction box on the housing.
WARNING: Power source must conform to requirements of the fixture
(see labels on fixture), all NEC and local electrical codes. Before starting
wire connections, disconnect power at circuit breaker or fuse, turning
power off at switch leg is not sufficient to prevent electrical shock.
Supply wire must be rated at 90°C or higher. Connect blacks to blacks
(hot), whites to whites (neutral), and greens to greens (ground) with
twist type wire connectors (not provided). (Fig. 3) Close junction box
cover after wiring (ensure that all wires are within box before closing).
6. Lamp holder caps are individually boxed at the bottom of the shipping
carton. Place proper lamp into the socket, noting indicated lamp and
maximum wattage on the housing labels. DO NOT EXCEED THE
ADVISED MAXIMUM WATTAGE. Space is provided within the
lampholder cap for lens and/or louver accessories. These elements are
held in place with the spring retaining ring; place front cap onto the twist
and lock mounting points.
7. The white trim frame may be mounted, after the ceiling is completed, by
compressing and placing the torsion springs into the slots mounted at
each end of the housing. Springs will hold the trim frame firmly to the
ceiling surface (Fig. 4).
For TRIMLESS installation: In dry wall ceiling, dry wall material should
be cut closely to size, any space between this material and the plaster
frame may be filled with compound. Plaster ceilings should be finished
to plaster frame that extends down from the Mounting Plate.
White to White
Black to Black
Ground Wire
INSTALLATION INSTRUCTIONS
For RAN New Construction Series Accentuate Concealed Adjustable Illumination Series
RAN15038, RAN7530, RAN5020, RAN75111, RAN5016, RAN7516, RAN7038MH, RAN10038MH, RAN2030MH,
RAN3530MH, RAN7030MH, RAN2020MH, RAN3520MH, RAN2016MH, RAN3916MH, RAN22BT5, RAN39BT5, RAN20T4,
RAN39T4, RAN70T4, RAN20T6, RAN39T6, RAN70T6, RAN38LEM, RAN10111