beautypg.com

ConTech Lighting RA6LRM User Manual

ConTech Lighting For the car

background image

White to White

Black to Black

Ground Wire

JOIST:

2" x 8"

3"

3"

3"

INSULATION

CEILING MATERIAL

Screws

INSTALLATION PROCEDURES

Housing can not be installed in direct contact with insulation. Do

not install insulation within 3" of fixture sides or wiring compartment, nor

above fixture in such a manner to entrap heat. (Figure 1)

• Using supplied template, scribe circle on ceiling in desired location and

accurately cut hole in ceiling.

• Make all necessary electrical connections (See “Electrical Connection”).
• With clips seated properly in can (Figure 3), insert housing through ceiling

opening, junction box first, until it is flush with ceiling.

• Hold fixture up against ceiling and push clip through housing slot.
• To lock clip into place, push flat portion against side of can in an upward

direction. (Figure 4A) To complete installation, push up clip with screw-

driver until it snaps into place. To release, pull down on clip. (Figure 4B)

ELECTRICAL CONNECTION:

• Provide electrical service with flexible cable only. Pass cable through

opening and wire fixture in accordance with NEC or local electrical code.

• Remove appropriate size knockout on fixture J-box for conduit.
• Remove J-box cover by pushing up on spring clip. Attach conduit with

connector to J-box and secure.

• Connect supply wires to fixture wires: connect black to black (hot), white

to white (neutral), and green to green (ground) with twist type wire

connectors (not provided). (Figure 2)

• Close junction box cover after wiring. Insure that all wires are safely

within box before closing.

• For 1000 Series Dimming, the 12D2 and 27D2 driver options can be

dimmed with 0-10V dimming controls. Locate low voltage dimming

control wires (purple, yellow) in junction box and make appropriate

connections (purple to purple, yellow to grey). The green wire should be

attached to the fixture’s ground leads. Please consult factory for

additional details. When using 0-10V dimming drivers, Class I wiring

(300V wiring inside conduit) is required.

• For 700 Series Dimming, the 12D1 driver option can be dimmed with

many standard 120V incandescent and electronic low voltage dimmers.

TRIM AND LED MODULE INSTALLATION:

• Remove protective cover from LED Module.
• For decorative trim assemblies with separate trim ring, place ring on

reflector prior to assembly.

• Attach reflector to LED Module with (2) screws (Figure 5). For trim

assemblies with lenses and/or two piece reflectors; complete the trim

assembly by positioning the lens and lower reflector in place.

• Make the LED Module electrical connection with the connectors (Figure 6).
• Carefully route excess wire out of the way; align tab in conduit base to

recess in heat-sink (Figure 6A) and snap into place making sure the tabs

are engaged with the recessed grooves. (Figure 6B)

• Push LED Module with assembled reflector through the hole in plaster

frame until flush with ceiling. Spring clip tension can be adjusted by

bending spring clips.

REPLACEMENT OF LED DRIVER:

NOTE: LED Driver should be replaced by a qualified electrician. Turn off

power at fuse or circuit breaker box before replacing the LED Driver.

• Pull and drop the trim and LED Module from the frame.

• Remove the conduit base from the LED Module by squeezing the sides

with tabs and pull apart (Figure 6). Disconnect the electrical connection.

• Remove J-Box cover with LED Driver Enclosure from J-Box by pushing

outward on spring clip (Figure 7).

• Disconnect LED Driver from line voltage input wiring in J-Box. Open up

the LED Driver Enclosure and disconnect the LED Driver from the LED

leads (leads are terminated by crimp connectors).

Continued

RA6LRM INST

For Con-Tech Lighting 6" LED Recessed Downlight Series: RA6LRM

www.con-techlighting.com

All specifications subject to change without notice.

Continued

1-847-559-5500

This document can be recycled.

A. To Install

B. To Remove

Driver Enclosure