beautypg.com

Inbox / outbox user manual, 4 – outbox x2, 1 – outbox x2 device specifications – Attero Tech InBox/OutBox User Manual

Page 30

background image

InBox / OutBox

User Manual

 Attero Tech LLC 2010

Page 25

614-00005-04

7.4 – OutBox X2

The CobraNet interface unit shall provide two balanced outputs on front panel with XLR connectors. The internal digital to
analog signal conversion shall be performed at 24-bit resolution with a sampling frequency of 48 kHz. The CobraNet
interface unit shall receive power over the Ethernet cable from an 802.3af compliant network switch. The CobraNet interface
shall be wall mounted in a standard dual gang junction box.

The CobraNet interface shall be compatible with Attero Tech Control Center software for flexible control and monitoring in
system applications. The CobraNet interface shall be compliant with the RoHS directive.

The CobraNet interface shall be the Attero Tech OutBox X2.

7.4.1 – OutBox X2 Device Specifications

CobraNet Network

Physical Level:

Standard Ethernet

Connector:

Single RJ-45

Cable Quality:

CAT-5

Transmission Speed:

100 Mbps

Power Requirements

48V via 802.3af PoE
compliant Ethernet switch

Power Consumption

4W

Dimensions

Main Unit: 3.59” x 2.72” x
1.965” (w x h x d)

Weight

0.75 lbs

Compliance

RoHS, FCC Part 15 Class B
Compliant

Audio Outputs

Output Type:

Balanced with automatic
muting upon loss of
CobraNet signal

Output Impedance:

200 Ω balanced,
100 Ω unbalanced

Maximum Output Level:

+10 dBu

Audio Performance:

System Noise:

-83 dBu

System THD+N:

< 0.006% - 1kHz input @ -3
dB below clipping

Frequency Response

20 Hz – 20 kHz, +/- 1 dB

Sample Rate

48 kHz only