beautypg.com

Inbox / outbox user manual, 2 – inbox r8, 1 – inbox r8 device specifications – Attero Tech InBox/OutBox User Manual

Page 28

background image

InBox / OutBox

User Manual

 Attero Tech LLC 2010

Page 23

614-00005-04

7.2 – InBox R8

The CobraNet interface unit shall provide eight line level analog inputs on front panel with RCA connectors. The internal
analog to digital signal conversion shall be performed at 24-bit resolution with a sampling frequency of 48 kHz. The
CobraNet interface unit shall receive power over the Ethernet cable from an 802.3af PoE compliant network switch. The
CobraNet interface shall be wall mounted in a standard dual gang junction box.

The CobraNet interface shall be compatible with Attero Tech Control Center software for flexible control and monitoring in
system applications. The CobraNet interface shall be compliant with the RoHS directive.

The CobraNet interface shall be the Attero Tech InBox R8.

7.2.1 – InBox R8 Device Specifications

CobraNet Network

Physical Level:

Standard Ethernet

Connector:

Single RJ-45

Cable Quality:

CAT-5

Transmission Speed:

100 Mbps

Power Requirements

48V via 802.3af PoE
compliant Ethernet switch

Power Consumption

4W

Dimensions

Main Unit: 3.59” x 2.72” x
1.965” (w x h x d)

Weight

0.75 lbs

Compliance

RoHS, FCC Part 15 Class B
Compliant

Audio Inputs

Input Type:

Single-ended, RF filtered

Input Impedance:

10 kΩ

Maximum Input
Levels:

+8.8 dBu

Audio Performance:

System Noise:

-82 dBu

System THD+N:

< 0.007% - 1 kHz input
@ 3 dB below clipping

Frequency Response

20 Hz-20 kHz, +/- 1 dB

Sample Rate

48 kHz only