Inbox / outbox user manual, 2 – inbox r8, 1 – inbox r8 device specifications – Attero Tech InBox/OutBox User Manual
Page 28
InBox / OutBox
User Manual
Attero Tech LLC 2010
Page 23
614-00005-04
7.2 – InBox R8
The CobraNet interface unit shall provide eight line level analog inputs on front panel with RCA connectors. The internal
analog to digital signal conversion shall be performed at 24-bit resolution with a sampling frequency of 48 kHz. The
CobraNet interface unit shall receive power over the Ethernet cable from an 802.3af PoE compliant network switch. The
CobraNet interface shall be wall mounted in a standard dual gang junction box.
The CobraNet interface shall be compatible with Attero Tech Control Center software for flexible control and monitoring in
system applications. The CobraNet interface shall be compliant with the RoHS directive.
The CobraNet interface shall be the Attero Tech InBox R8.
7.2.1 – InBox R8 Device Specifications
CobraNet Network
Physical Level:
Standard Ethernet
Connector:
Single RJ-45
Cable Quality:
CAT-5
Transmission Speed:
100 Mbps
Power Requirements
48V via 802.3af PoE
compliant Ethernet switch
Power Consumption
4W
Dimensions
Main Unit: 3.59” x 2.72” x
1.965” (w x h x d)
Weight
0.75 lbs
Compliance
RoHS, FCC Part 15 Class B
Compliant
Audio Inputs
Input Type:
Single-ended, RF filtered
Input Impedance:
10 kΩ
Maximum Input
Levels:
+8.8 dBu
Audio Performance:
System Noise:
-82 dBu
System THD+N:
< 0.007% - 1 kHz input
@ 3 dB below clipping
Frequency Response
20 Hz-20 kHz, +/- 1 dB
Sample Rate
48 kHz only