Page 44
Serial/USB Port Commands
1. Alarm
alarm
Description: Display all the alarm settings
Arguments:
Example: alarm
Response:
Minimum Fan RPMs:
- Fan 1: 100
- Fan 2: 100
- Fan 3: 100
- Fan 4: 100
Device Temperatures (Celsius):
- Temp min: 0
- Temp max: 70
Notification
Method:
- Beep: ON
- Serial Port: ON
- Email: OFF
Power
supply:
1
(or an error message if the command failed)
alarm -f
Description: Set the minimum RPM value for a fan(s) before an alarm is raised
Arguments:
Example:
Set the minimum RPM to 150 for all fans before an alarm is raised
alarm –f all 150
Response:
Minimum RPM value(s) for fan(s) applied successfully!
(or an error message if the command failed)
alarm -p
<# of power supply>
Description: To indicate if the unit has 1 or 2 power supplies
Arguments:
<# of power supply>: 1 or 2
Example:
Indicate if the unit has 2 power supplies
alarm –p 2
Response:
Power supply information saved successfully !
(or an error message if the command failed)
alarm -t
Description: Set the minimum and maximum temperatures value before an alarm is raised
Arguments:
Example:
Set the minimum and maximum temperature to respectively 5 and 70 degree celsius, before an
alarm is raised
alarm –t 5 70
Response:
Minimum and Maximum temperatures applied successfully !
(or an error message if the command failed)