Technical reference, Pump station numbering system, Pump station with e-sv pumps – Bell & Gossett 10 001 247 R3 TechnoForce Package System User Manual
Page 28
![background image](/manuals/463360/28/background.png)
Technical Reference
Pump station numbering system
The pump station label located on the inside of the control enclosure door identifies the
product code number for the various versions of the pump systems. This number is also
the catalog number for the pump station. The pump station numbering systems describe
the meaning of each digit.
Not all combinations are possible.
Pump station with e-SV pumps
Example product code
V
2
VF
C
2
A
2
1
A
1
BCD
Numbering system definitions
First character: Variable or constant speed
V = variable speed
X = XLS variable speed
C = constant speed
Second character: Number of pumps
2, 3, or 4
Third character: Pump type and size
VA = 1SV
VG = 33SV
VB = 3SV
VH = 46SV
VC = 5SV
VJ = 66SV
VD = 10SV
VK = 92SV
VE = 15SV
VM = 125SV
VF = 22SV
Fourth character: Header size
C = 3 in.
E = 6 in.
D = 4 in.
F = 8 in.
Fifth character: Supply voltage
2 = 208 V / 1 PH / 60 Hz
6 = 460 V / 3 PH / 60 Hz
3 = 230 V / 1 PH / 60 Hz
7 = 575 V / 3 PH / 60 Hz
4 = 208 V / 3 PH / 60 Hz
8 = 380 V / 3 PH / 60 Hz
5 = 230 V / 3 PH / 60 Hz
9 = 380 V / 3 PH / 50 Hz
Sixth character: HP rating
A = 1/2
E = 2
J = 10
N = 30
T = 75
B = 3/4
F = 3
K = 15
P = 40
U = 100
C = 1
G = 5
L = 20
R = 50
V = 125
D = 1-1/2
H = 7-1/2
M = 25
S = 60
W = 150
Technical Reference
26
TechnoForce and TechnoForce XLS Package System Mechanical Installation, Operation, and Maintenance
Manual