Install the packed stuffing box, Install the pump, driver, and coupling – Goulds Pumps API 3171 - IOM User Manual
Page 23

Install the packed stuffing box
WARNING:
Packed stuffing boxes are not allowed in an ATEX-classified environment.
The stuffing box is packed at the factory. The packing is lubricated by a grease cup supplied with the
pump.
1. Fill the grease cup with any lithium-based #2 grease.
2. Install the grease cup on the tapped opening on the stuffing box.
3. Turn the cap on the grease cup several turns in order to inject the grease into the packing.
4. Hand-tighten the gland nuts.
355
193I
494V
367B
106
221
107
353
355C
105
364A
190G
105
Lantern ring
353
Gland stud
106
Packing set
355
Gland nuts
107
Gland
355C
Insert nuts
190G
Pipe nipple
364A
Packed box insert
193I
Grease cup
367B
Insert gasket
221
Stuffing box support
494V
Pipe elbow
Install the pump, driver, and coupling
1. Mount and fasten the pump on the baseplate. Use applicable bolts.
2. Mount the driver on the baseplate. Use applicable bolts and hand tighten.
3. Install the coupling.
See the installation instructions from the coupling manufacturer.