Electrical connections – Minka Group F707-FLP User Manual
Page 12

5
WARNING:To avoid possible electrical shock be sure electricity is
turned off at the main fuse or breaker box before wiring.
Step 1.Insert Receiver into Hanger Bracket with the flat side of the Recei-
ver facing the ceiling. (Fig. 13)
Step 2.Motor to Receiver Electrical Connections: Connect the WHITE
wire from the fan to the WHITE wire marked "TO MOTOR N" from the
Receiver. Connect the BLACK wire from the fan to the BLACK wire
marked "TO MOTOR L" from the Receiver. Connect the BLUE wire from
ELECTRICAL CONNECTIONS
the fan to the BLUE wire marked "For Light" from the Receiver.
Note: If your ceiling fan features an UP Light: Connect the ORANGE wire
from the fan to the ORANGE wire marked "For Up Light" from the
Receiver. Otherwise disregard this step and proceed to secure all wire
connections with the plastic wire nuts provided. (Fig. 14 & 15)
Step 3. Receiver to House Supply Wires Electrical Connections: Connect the
WHITE wire (Neutral) from the outlet box to the WHITE wire marked "AC in
N" from the receiver. Connect the BLACK wire (Hot) from the outlet box to
the BLACK wire marked "AC in L" from the receiver. Secure all wire
connections with the plastic wire nuts provided. (Fig. 14 & 15)
Note: The Aire Control System is equipped with a learning frequency
function which has 256 code cominations to prevent potential interference
from other remote units. The frequency on your Receiver and Transmitter units
have been preset at the factory.(Fig.12). No frequency change is necessary,
should you desire to install another fan within the same home or area with
a seperate frequency code please see the “frequency interference ” troub-
leshooting section of this instruction manual to learn how to change the
frequency.