beautypg.com

Electrical connections – Minka Group F707-FLP User Manual

Page 12

background image

5

WARNING:To avoid possible electrical shock be sure electricity is

turned off at the main fuse or breaker box before wiring.

Step 1.Insert Receiver into Hanger Bracket with the flat side of the Recei-

ver facing the ceiling. (Fig. 13)
Step 2.Motor to Receiver Electrical Connections: Connect the WHITE

wire from the fan to the WHITE wire marked "TO MOTOR N" from the

Receiver. Connect the BLACK wire from the fan to the BLACK wire

marked "TO MOTOR L" from the Receiver. Connect the BLUE wire from

ELECTRICAL CONNECTIONS

the fan to the BLUE wire marked "For Light" from the Receiver.
Note: If your ceiling fan features an UP Light: Connect the ORANGE wire

from the fan to the ORANGE wire marked "For Up Light" from the

Receiver. Otherwise disregard this step and proceed to secure all wire

connections with the plastic wire nuts provided. (Fig. 14 & 15)
Step 3. Receiver to House Supply Wires Electrical Connections: Connect the

WHITE wire (Neutral) from the outlet box to the WHITE wire marked "AC in

N" from the receiver. Connect the BLACK wire (Hot) from the outlet box to

the BLACK wire marked "AC in L" from the receiver. Secure all wire

connections with the plastic wire nuts provided. (Fig. 14 & 15)

Note: The Aire Control System is equipped with a learning frequency

function which has 256 code cominations to prevent potential interference

from other remote units. The frequency on your Receiver and Transmitter units

have been preset at the factory.(Fig.12). No frequency change is necessary,

should you desire to install another fan within the same home or area with

a seperate frequency code please see the “frequency interference ” troub-

leshooting section of this instruction manual to learn how to change the

frequency.