Drive Error Code Information:
In the event of a trip, an error code is returned in the High Byte of the drive status word. The fault values correspond to the
following table.
Fault
Code
No.
Description
Fault
Code
No.
Description
no‐Flt
00
No Fault
AtF‐01
40
Measured motor stator resistance varies between phases.
OI‐b
01
N/A
AtF‐02
41
Measured motor stator resistance is too large.
OL‐br
02
N/A
AtF‐03
42
N/A
O‐I
03
Instantaneous over current
AtF‐04
43
N/A
I.t‐trp
04
Motor Thermal Overload (I2t)
AtF‐05
44
N/A
SAFE‐1
05
Safety input circuit error (Processor output)
AtF‐06
45
Reserved
O‐Volt
06
Over voltage on DC bus
AtF‐07
46
Reserved
U‐Volt
07
Under voltage on DC bus
AtF‐08
47
Reserved
O‐t
08
Heatsink over temperature
AtF‐09
48
Reserved
U‐t
09
Under temperature
AtF‐10
49
Reserved
P‐
dEF
10
Factory Default parameters have been loaded
SC‐F01
50
Modbus comms loss fault
E‐trip
11
External trip
SC‐F02
51
BACNet comms loss trip
SC‐ObS
12
Optibus comms loss
SC‐F03
52
Anybus module comms loss trip
FLt‐dc
13
DC bus ripple too high
SC‐F04
53
IO card comms loss trip
P‐LOSS
14
Input phase loss trip
SC‐F05
54
Reserved
h O‐I
15
Instantaneous over current on drive output.
SC‐F06
55
Reserved
th‐Flt
16
Faulty thermistor on heatsink.
SC‐F07
56
Reserved
dAtA‐F
17
Internal memory fault. (IO)
SC‐F08
57
Reserved
4‐20 F
18
4‐20mA Signal Lost
SC‐F09
58
Reserved
dAtA‐E
19
Internal memory fault. (DSP)
SC‐F10
59
Reserved
U‐dEF
20
User Default Parameters Loaded
OF‐01
60
Internal link to option module loss
F‐Ptc
21
Motor PTC thermistor trip
OF‐02
61
Option module in exceptional condition
FAN‐F
22
Cooling Fan Fault
OF‐03
62
Reserved
O‐hEAt
23
Environmental temperature too high
OF‐04
63
Reserved
O‐torq
24
Over torque (HVAC
OF‐05
64
Reserved
U‐torq
25
Under torque (HVAC)
OF‐06
65
Reserved
Out‐F
26
Drive output fault
OF‐07
66
Reserved
Err‐01
27
Reserved
OF‐08
67
Reserved
Err‐02
28
Reserved
OF‐09
68
Reserved
SAFE‐2
29
Safety input circuit error (Buffer output)
OF‐10
69
Reserved
Enc‐01
30
N/A
PLC‐01
70
Unsupported PLC function block
Enc‐02
31
N/A
PLC‐02
71
PLC program over size
Enc‐03
32
N/A
PLC‐03
72
Divide by 0
Enc‐04
33
N/A
PLC‐04
73
Lower limit large than higher limit
Enc‐05
34
N/A
PLC‐05
74
Table function block index overflow
Enc‐06
35
N/A
PLC‐06
75
Reserved
Enc‐07
36
N/A
PLC‐07
76
Reserved
Enc‐08
37
N/A
PLC‐08
77
Reserved
Enc‐09
38
N/A
PLC‐09
78
Reserved
Enc‐10
39
N/A
PLC‐10
79
Reserved