Hardware Self Test

9

Hardware Self Test

The self test program can be used to test aspects of operator panel functionality
and the communication ports. To run the test you will need:

Test plugs, including two Ethernet test plugs; see

Test plug drawing

.

24 V DC, min. 3 A.

SD card

Follow the steps below to run the self test program on the operator panel:
1. Power off the operator panel.
2. Go to the self test. Set the mode switches to the self test positions, see the table

in the

Mode Switches

section.

3. Power on the operator panel and follow the instructions at the bottom of the

display.

4. When using the test plugs, make sure the +5 V DC LED on the RS422 test

plug and the LED of the RS232 test plug are on.

5. When the self test is finished, power off the operator panel and set all mode

switches to the OFF position.

If an error occurs during the self test, try to fault trace. See

Fault Tracing

.