SPANNING

• AZEK Trim and Moulding products must not be used in load bearing applications, but may be

used in spanned applications such as fascias, soffits and ceilings. For optimal performance,
AZEK Trim and Mouldings should be installed over a solid backing.

• FOR SOFFIT INSTALLATIONS:

• For spans greater than 16” OC, see below.
• When using AZEK Beadboard, see considerations below.

• FOR CEILING INSTALLATIONS:

• For spans greater than 16” OC, see below.
• If temperature at time of installation is 40˚F or below, spans need to be decreased to 12”.
• When using AZEK Beadboard, see consideration below.

• AZEK BEADBOARD SPANNING CONSIDERATION:

• For both 1/2” and 5/8” AZEK Beadboard, run boards perpendicular to structure when

possible to create the shortest possible run of material.

• When using 1/2” AZEK Beadboard, use 12” OC framing as well as a high quality construction

grade polyurethane adhesive on joists.

– For spans greater than 12” OC, use 5/8” AZEK Beadboard or use a minimum 1/2” backer

such as plywood or OSB with construction grade adhesive and mechanical fastening a
minimum of every 8”. Fasteners should hit joist or framing when possible.

• When using 5/8” AZEK Beadboard, use 16” OC framing as well as a high quality construction

grade polyurethane adhesive on joists. For spans greater than 16” OC, see below.

• For spans greater than 16” OC, use a minimum 1/2” backer such as plywood or OSB with

construction grade adhesive and mechanical fastening a minimum of every 16”. Fasteners
should hit joist or framing when possible.

• Never span AZEK products more than 16” without utilizing instructions above. Proper fastening

will help reduce the possibility of excessive movement from expansion and contraction.

• With all Beadboard or Trim ceiling and soffit installations, follow good building practices and

ensure adequate ventilation is provided.

WATER TABLE

Mechanically fasten water table to trimboard and wall structure

according to standard AZEK Trim and Moulding Guidelines.

Fasten in center (top to bottom) of nailing flange

Apply AZEK Adhesive

to join Water Table to

Trimboard

Adhesive

IMPORTANT: Flash according to water barrier manufacturer

guidelines. Use common accepted building practices to prevent

water infiltration.

SIZE

• 2

3

4

” x 2” in 18’

lengths

• 1

1

2

” tapered starter

strip/nailing flange

height

3

8

” thick starter

strip/nailing flange

(at its thickest point)

Fasten trimboard according to standard

AZEK Trim guidelines.

Installation Guidelines for AZEK Trim and AZEK Moulding