3

MAINTENANCE

Cleaning
Beginning with the initial installation, the interior surfaces of the cabinet should be
periodically cleaned with a solution of warm water and baking soda. This solution will
remove any odors from spillage that has occurred. The exterior of the cabinet should
also be cleaned frequently with a commercial stainless steel cleaner, glass cleaner or
mild soap solution. Do not use chlorinated cleaners on the stainless steel surfaces.

The door gaskets should be cleaned in place with a mild soap solution to extend their
life.

The shelving can be cleaned in a sink with a mild soap solution and a soft bristled
brush.

Condenser Coil
Disconnect the unit from power prior to cleaning the condenser coil. Periodic cleaning of
the condenser coil will aid the heat transfer of the refrigeration system and increase its
efficiency. Cleaning is recommended a minimum of every 6 months. To accomplish
this, remove the lower front grill from the cabinet. The condenser coil is located behind
the grill. Use a soft bristled brush to remove any dirt particles that are on the fins of the
condenser coil. Use a vacuum cleaner or compressed air to remove the loosened
particles. Replace the front grill and reconnect the unit to power. Failure to clean the
condenser coil can lead to performance loss and compressor failure.

ELECTRONIC CONTROL


1. ELECTRONIC CONTROLLER DISPLAY PANEL LAYOUT














Power On

Door Open

Down Button

Mode/Set Button

Up Button

Manual DF/
Verify Button

Displays Cabinet Temperature
or Current Mode

Compressor ON