Merrychef eikon e6 User Manual
Page 52

E6 SERVICE MANUAL REV C 06/12
52
Error
Code
Oven Series
Error/Event
Condition
Description
Trigger
Error
Level
System
Response
E122
E2
Radiant Off
Radiant heater
element failed to
turn On
Not Implemented
Yet
Critical
"E122 NO
RADIANT ON
REQUEST"
message is
written to the
error log.
E6
The current
measured by the
SRB is lower than
what is expected.
The calculation is
affected by the
E123
None
Elevator failed
The food elevator
has failed.
The system
determined that
the food elevator is
not operating
correctly.
Critical
"E123
ELEVATOR
FAILED"
message is
displayed in the
error log.
E124
E6
Left Magnetron
overheat
The left
magnetron
thermal switch
has released but
the condition
clears in time
The left magnetron
thermal cut-out has
released while the
left magnetron is
running and the
condition clears
Warning
"E124 LEFT
MAGNETRON
OVER
HEATED"
message is
displayed in the
The left
magnetron
thermal switch
has released but
the condition does
not clear in time
The left magnetron
thermal cut-out has
released while the
left magnetron is
running and the
condition has not
Critical
"E124 LEFT
MAGNETRON
OVER
HEATED"
message is
displayed in the
E125
None
Left Magnetron failed
Left Magnetron
failed to turn On
when requested
The current
measured by the
SRB was outside
of the tolerance
range
Critical
"E125 LEFT
MAGNETRON
FAILED"
message is
written to the
error log.
E126
None
Left Magnetron On
without request
Left magnetron
failed to turn OFF
The left magnetron
current measured
by the SRB was
outside of the
tolerance range
Critical
"E126 LEFT
MAGNETRON
ON WITHOUT
REQUEST"
message is
written to the
E127
E2, E6
QTS board sensor
failed
The temperature
sensor on the
QTS board is no
longer operating
The QTS is
reading an open or
shorted sensor
mounted on the
board
Critical
"E127 QTS
AMBIENT
SENSOR
CIRCUIT
FAILED"
message is