Merrychef eikon e6 User Manual
Page 50

E6 SERVICE MANUAL REV C 06/12
50
Error
Code
Oven Series
Error/Event
Condition
Description
Trigger
Error
Level
System
Response
E114
None
Spare (not used)
N/A
N/A
N/A
N/A
E115
E6
Convection Fan failed
The convection
fan has failed
The feedback from
the convection fan
controller has
indicated to the
SRB that the
controller has
Critical
"E115
CONVECTION
FAN
FEEDBACK"
message is
written to the
E116
E2, E3, E4, E5
Heater off
Convection heater
element failed to
turn On
The SRB senses
that the heater
current is <1 amp
when requested to
be ON
Critical
"E116 NO
HEATER ON
REQUEST"
message is
written to the
error log.
E6
High Heater off
High convection
heater element
failed to turn On
The SRB senses
that the high
heater current is
<1 amp when
requested to be
ON
"E116 NO HIGH
HEATER ON
REQUEST"
message is
written to the
error log.
E117
E3, E4, E5
Magnetron overheat
One or both of the
magnetrons
thermal switch's
has released but
the condition
clears in time
One or both of the
magnetron thermal
cut-outs has
released while one
or both
magnetrons are
Warning
"E117
MAGNETRON
OVERHEAT"
message is
written to the
error log.
One or both of the
magnetrons
thermal switch's
has released but
the condition does
not clear in time
One or both of the
magnetron thermal
cut-outs has
released while one
or both
magnetrons are
Critical
"E117
MAGNETRON
OVERHEAT"
message is
displayed in the
error log.
E2, E3
Magnetron overheat
The magnetron
thermal switch
has released but
the condition
clears in time
The magnetron
thermal cut-outs
has released while
the magnetron is
running and the
condition clears
Warning
"E117
MAGNETRON
OVERHEAT"
message is
written to the
error log.
The magnetron
thermal switch
has released but
the condition does
not clear in time
The magnetron
thermal cut-outs
has released while
the magnetron is
running and the
condition has not
Critical
"E117
MAGNETRON
OVERHEAT"
message is
displayed in the
error log.