Error codes displayed – Merrychef eikon e6 User Manual
Page 45

E6 SERVICE MANUAL REV C 06/12
45
ERROR CODES DISPLAYED
Error
Code
Oven Series
Error/Event
Condition
Description
Trigger
Error
Level
System
Response
E000
All
OK
Communication
between the QTS
and the SRB has
been
reestablished.
The SRB was
previously in a
communication
error state (E107)
and the error has
now cleared.
N/A
"E088 OK"
message is
displayed in the
error log.
This message is
di l
d
E083
E2, E6
Incompatible SRB
software version
SRB firmware
version is
incompatible with
the QTS version
The QTS has
found that the
firmware running
the SRB is not
supported.
Critical
"E083 SRB
VERSION
CONFLICT"
message is
displayed in the
error log.
E084
E2, E6
Invalid Date
The QTS has
determined that
the state of the
Real Time Clock
(RTC) is invalid
Only tested for
when oven turns
on. The QTS has
found that the
system date is
2010 or earlier.
Warning
"E084 INVALID
DATE" message
is displayed in
the error log.
"INVALID
DATE"
Only tested for
when oven turns
on. The QTS has
found that the RTC
has an invalid
date/time setting or
E085
None
Recommission fail -
Elevator
The elevator
failed the
recommission test
N/A
N/A
"E085
RECOMMISSIO
N FAIL
ELEVATOR"
message is
displayed in the
E086
E2, E6
Recommission fail -
Radiant
The radiant
heater failed the
recommission test
Pressing the "Red
X" when
"RADIANT TEST
IN PROGRESS " is
displayed
N/A
"E086
RECOMMISSIO
N FAIL
RADIANT"
message is
displayed in the
E087
E6
Recommission fail -
Low Heater
The low
convection heater
failed the
recommission test
Pressing the "Red
X" when "LOW
HEATER TEST IN
PROGRESS" is
displayed
N/A
"E087
RECOMMISSIO
N FAIL LOW
HEATER"
message is
displayed in the
E088
All
Low or High line
voltage
The Mains AC
supply voltage is
out of range
The QTS
determines that the
AC mains voltage
read from the SRB
is out of the ±10%
tolerance range
Warning
"E088 SUPPLY
VOLTAGE (V)
OUT OF
RANGE"
message is
displayed in the