HOUNO CombiSlim C User Manual
Page 13

C – Ver. 9.02 – June 2011
13
17 Injection
interval 2
Combi steaming 2: See 18 (factory setting is every 5 seconds)
18 Injection
interval R
Regenera-
ting/reheating
Setting of humidity pulsing. Press temperature key and turn switch to
change setting. The value indicates the number of seconds between each
injection into the oven chamber. If the value is increased, less humidity
is added to the oven chamber, if the value is reduced, more humidity is
added (factory setting is every 8 seconds).
19 Save all
Press ALARM to make a backup of all settings in all modes and
programmes.
20 Retrieve all
Press ALARM to retrieve all settings saved in all modes and programmes.
21 Restart
Not in use.
22 Screen saver
Interval of seconds before screen saver becomes active. 0 = 0 sec. / 1 =
10 sec. / 2 = 30 sec. / 3 = 60 sec./ 4 = 180 sec. / 5 = 600 sec. Change
by pressing STEP.
23 Language
Change by pressing STEP (1 – 9).
24 SW update
Updating of software. Special memory key required. Contact your local
distributor.