HOUNO CombiSlim C User Manual
Page 13

C – Ver. 9.02 – June 2011
13
 
17 Injection 
interval 2
Combi steaming 2: See 18 (factory setting is every 5 seconds)
18 Injection
interval R 
Regenera-
ting/reheating 
Setting of humidity pulsing. Press temperature key and turn switch to 
change setting. The value indicates the number of seconds between each 
injection into the oven chamber. If the value is increased, less humidity 
is added to the oven chamber, if the value is reduced, more humidity is 
added (factory setting is every 8 seconds). 
19 Save all
Press ALARM to make a backup of all settings in all modes and 
programmes. 
20 Retrieve all
Press ALARM to retrieve all settings saved in all modes and programmes.
21 Restart
Not in use.
22 Screen saver
Interval of seconds before screen saver becomes active. 0 = 0 sec. / 1 = 
10 sec. / 2 = 30 sec. / 3 = 60 sec./ 4 = 180 sec. / 5 = 600 sec. Change 
by pressing STEP. 
23 Language
Change by pressing STEP (1 – 9).
24 SW update
Updating of software. Special memory key required. Contact your local 
distributor. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
