In use

Maintenance

• To clean the computer or accessories, use diluted neutral detergent on

a soft cloth, and wipe it off with a dry cloth.

• Since the HR strap directly touches your skin, keep it clean by washing

off any dirt after use.

Replacing the battery

Computer

1

Replace the lithium battery

When (battery icon) is turned on, re-

place the battery. Install a new lithium

battery (CR2032) with the (+) side facing

upward.

* Press the top edge of

waterproof inner cap

to remove it. Install

the cap with the “TOP

faced upward.

TOP

2

Press the AC button on the back of

the computer (Restarting operation)

* When restarting, the speed unit, sensor

ID, sensor currently synchronized, tire

circumference, upper display setting,

and total distance are retained.

3

Set the Clock

Pressing and holding the MODE button

switches the display to “Displayed time”,

“Hour”, and “Minute” in order.

MODE

12h 24h

or increase the value

MODE

Switch the screen

or move digits

4

Press the MENU button to complete setting

MENU

Register the setting

(Finish)

TOP

TOP

CR2032

AC

Click

Waterproof

inner cap

Heart rate sensor

* When the heart rate flashes, replace the battery.

Insert new lithium batteries (CR2032) with the (+) sign upward, and close

the battery cover firmly.

COIN

CR2032

* Reset the sensor by pressing RESET button when you replace the sen-

sor battery.

Speed sensor

* When the current speed flashes, replace the speed sensor battery.

Insert new lithium batteries (CR2032) with the (+) sign upward, and close

the battery cover firmly.

COIN

CR2032

* After replacement, check the position in respect to the magnet.
* Reset the sensor by pressing RESET button when you replace the sen-

sor battery.

Close

Close

Open

Open

Battery

case

cover

Display format

Hour Minute

Troubleshooting

The current speed / heart rate cannot be measured.

Check that the clearance between the sensor and magnet is

not too large. (Clearance: within 3 mm)

Check that the magnet passes through the sensor zone cor-

rectly.

Adjust the positions of the magnet and sensor.

Is the heart rate sensor attached securely to your body?

Adjust the electrode pad to have a good contact with the

body.

Is the electrode pad overly worn and damaged after long use?

Replace it with a new HR strap.

Is there any problem in searching the sensor ID?

Search the sensor ID according to the procedure speci-

fied in the section “Changing the computer setting /

Searching for sensor ID” (Page 8).

Does the computer or sensor indicate when to replace the bat-

tery?

Replace with new batteries according to the procedure

specified in the section “Replacing the battery.”

Nothing is displayed by pressing the button.

Replace the computer battery according to the procedure

specified in the section “Replacing the battery”.

Incorrect data appear.

Restart according to the procedure specified in the section

“Replacing the battery / Computer, steps 2 to 4”.

The measurement data is wrong.

(The maximum speed is too high, etc.)

Are there any objects emitting electromagnetic waves (railway

tracks, transmitting stations for television, Wi-Fi environment, etc.)

nearby?

Keep the unit away from any object that may be the cause.

Perform the resetting operation in the case of invalid data.