Replacing the battery, Troubleshooting, Cc-rd430dw eng 9 – CatEye CC-RD430DW [Strada Digital Wireless] User Manual
Page 9
CC-RD430DW
ENG
9
In use
Maintenance
• To clean the computer or accessories, use diluted neutral detergent on
a soft cloth, and wipe it off with a dry cloth.
• Since the HR strap directly touches your skin, keep it clean by washing
off any dirt after use.
Replacing the battery
Computer
1
Replace the lithium battery
When (battery icon) is turned on, re-
place the battery. Install a new lithium
battery (CR2032) with the (+) side facing
upward.
* Press the top edge of
waterproof inner cap
to remove it. Install
the cap with the “TOP”
faced upward.
TOP
2
Press the AC button on the back of
the computer (Restarting operation)
* When restarting, the speed unit, sensor
ID, sensor currently synchronized, tire
circumference, upper display setting,
and total distance are retained.
3
Set the Clock
Pressing and holding the MODE button
switches the display to “Displayed time”,
“Hour”, and “Minute” in order.
MODE
12h ↔ 24h
or increase the value
MODE
Switch the screen
or move digits
4
Press the MENU button to complete setting
MENU
Register the setting
(Finish)
TOP
TOP
CR2032
AC
Click
Waterproof
inner cap
Heart rate sensor
* When the heart rate flashes, replace the battery.
Insert new lithium batteries (CR2032) with the (+) sign upward, and close
the battery cover firmly.
COIN
CR2032
* Reset the sensor by pressing RESET button when you replace the sen-
sor battery.
Speed sensor
* When the current speed flashes, replace the speed sensor battery.
Insert new lithium batteries (CR2032) with the (+) sign upward, and close
the battery cover firmly.
COIN
CR2032
* After replacement, check the position in respect to the magnet.
* Reset the sensor by pressing RESET button when you replace the sen-
sor battery.
Close
Close
Open
Open
Battery
case
cover
Display format
Hour Minute
Troubleshooting
The current speed / heart rate cannot be measured.
Check that the clearance between the sensor and magnet is
not too large. (Clearance: within 3 mm)
Check that the magnet passes through the sensor zone cor-
rectly.
Adjust the positions of the magnet and sensor.
Is the heart rate sensor attached securely to your body?
Adjust the electrode pad to have a good contact with the
body.
Is the electrode pad overly worn and damaged after long use?
Replace it with a new HR strap.
Is there any problem in searching the sensor ID?
Search the sensor ID according to the procedure speci-
fied in the section “Changing the computer setting /
Searching for sensor ID” (Page 8).
Does the computer or sensor indicate when to replace the bat-
tery?
Replace with new batteries according to the procedure
specified in the section “Replacing the battery.”
Nothing is displayed by pressing the button.
Replace the computer battery according to the procedure
specified in the section “Replacing the battery”.
Incorrect data appear.
Restart according to the procedure specified in the section
“Replacing the battery / Computer, steps 2 to 4”.
The measurement data is wrong.
(The maximum speed is too high, etc.)
Are there any objects emitting electromagnetic waves (railway
tracks, transmitting stations for television, Wi-Fi environment, etc.)
nearby?
Keep the unit away from any object that may be the cause.
Perform the resetting operation in the case of invalid data.
SPD / CDC