Filtration and Ozone

On non-circ systems, Pump 1 low and the ozone generator will run during
filtration. On circ systems, the ozone will run with the circ pump.

The system is factory-programmed with one filter cycle that will run in the
evening (assuming the time-of-day is properly set) when energy rates are often
lower. The filter time and duration are programmable. A second filter cycle can
be enabled as needed.

At the start of each filter cycle, the blower (if there is one) or Pump 2 (if there is
one) will run briefly to purge its plumbing to maintain good water quality.

READY

RANGE FLTR1

JETS

TS

S

JJ

AUX

U

X

A

LIG

H

IGHT

T

H

HEAT

AT

T

JETS

AUX

LIGHT

HEAT

Circulation Pump Modes

If the system is equipped with a circ pump, it may be configured to work in one
of three different ways:

The circ pump operates continuously (24 hours) with the exception of turning

t

off for 30 minutes at a time when the water temperature reaches 3°F (1.5°C)
above the set temperature (most likely to happen in very hot climates).

The

t

circ pump stays on continuously, regardless of water temperature.

A

t

programmable circ pump will come on when the system is checking

temperature (polling), during filter cycles, during freeze conditions, or when
another pump is on.