Revolution

Transforming the Control of Hot Tubs

24

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,

834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

Mode -- Ready and Rest (cont.)

Ready Mode

READY Mode will allow the spa to

t

Poll and determine a need for heat. The

panel will maintain a “current” temperature display.

Rest Mode

REST Mode will not Poll and will only heat during filter cycles. The panel will

t

not display a current temperature at all times.

The Main Screen will display normally during Filter Cycles or when the spa is

t

in use.

If the

t

filtration pump has been off for an hour or more, and when any function

button (except Light) is pressed on the panel, the pump used in conjunction
with the heater will run so that the temperature can be sensed and displayed.

REST RANGE FLTR1

REST RANGE

REST RANGE

REST RANGE

REST RANGE

REST RANGE

Rest Mode: The Screen will display RUN PUMP FOR TEMP if the
filtration pump has not run for over 1 hour.

After one hour...

Ready-in-Rest Mode Appears in the Display

READY/REST appears in the display if the spa is in Rest Mode and Jet 1
is pressed. It is assumed that the spa is being used and will heat to set
temperature. While Pump 1 High can be turned on and off, Pump 1 Low will run
until set temperature is reached, or 1 hour has passed. After 1 hour, the System
will revert to Rest Mode. This mode can also be reset by entering the Mode
Menu and changing the Mode.

REST RANGE

READY/REST RANGE