Alarm History Table

There are 1000 alarm records stored in chronological
order in 125 pages of table.

1. Select a desired monitor. (Refer to p. 27 Monitor

Selection.)

2. Press the ALM RECALL button. "AlarmHist" will

appear on the LCD, and the ALARM HISTORY
table will be displayed on the active monitor.

ALM: Logical alarm number
STATE: Indicates alarm state changes.

ARMED: The system is armed for alarm

response.

ACTIVE: Alarm has been triggered and activat-

ed assigned alarm response.

ACKED: Alarm is acknowledged and an opera-

tor can control the alarm action.

RESET: Activated alarm is reset, but the alarm

device is still active.

DISARMED: The system is disarmed for alarm

response.

CLEARED: Auto arming is not set in the admin

console.

DATE/TIME: Date and time when alarm state

changes.

3. To display the next page, press the + button.
To display the previous page, press the – button.

MON AlarmHist CAM

0123 00512

ALARM HISTORY PG
ALM STATE DATE/TIME
1 DISARMED 01/01/01 12:00
1 ARMED 01/01/01 12:00
1 ACTIVE 01/01/01 12:00
1 ACKED 01/01/01 12:00
1 CLEARED 01/01/01 12:00
1 RESET 01/01/01 12:00

Note:

• To display the first page of table, press the + but-

ton while holding down the SHIFT button.

• To display the last page of table, press the – button

while holding down the SHIFT button.

• Every time you press the button 0 while holding

down the MON (ESC) button, the monitor back-
ground will change beween camera images and
black picture.

4. To exit the ALARM HISTORY table, press the

CLEAR button while holding down the MON (ESC)
button.

Note:

• This feature is available in only WJ-SX650 or

WJ-SX850 because of OSD limitation.