Alarms

To trigger alarms, setup the alarm source devices and register them to Alarm Source database by using Admin
Console.

# Alarm Type

Alarm Source

How to setup

Alarm source setup in
Admin Console

1 Camera Motion

analog camera

Turn on MOTION DET setting in dedicated camera
menu.

Select Motion (cam)

i-Pro cam

1. Select ON for i-Pro device's VMD alarm.
2. Set the Server IP Address to i-Pro devices' alarm

notification destination IP Address field. Also set
the port number 1818.

2 I/O Port (Dry con-

tact) alarm

analog digital input port in
SX850 or SX650 cage

Select SX850 or SX650 node and Register the input
port setting to Admin I/O Ports menu

Select I/O Port

i-Pro device
(i-Pro camera,
i-Pro decoder, DVR)

1. Select ON for i-Pro devices' Terminal alarm.
2. Set the Server IP Address to i-Pro devices' alarm

notification destination IP Address field. Also set
the port number 1818.

Select I/O Port

3 RS232C alarm

External system's RS232C
I/F

Select RS232 Controller Model for desired port in
Admin Controllers menu

Select RS232

4 Video Loss (any)

one of analog cameras via
SX850 or SX650 cage

Turn on Alarm Trigger check box in Admin Cameras
menu.

Select Vid Loss (any)

5 Video Loss (cam)

a certain analog camera via
SX850 or SX650 cage

Turn on Alarm Trigger check box in Admin Cameras
menu.

Select Vid Loss (cam)

6 Global Alarm

Other domains alarms and
do not care about alarm type

Select one or more than one domain that the global
alarm should be exported in Admin Alarms menu,
Export tab, UNIT partition menu.

Select Global Alarm

7 Scene change

detection

WV-NP1000
WV-NP1004
WV-NW484S

1. Select ON for NP1000's Scene change detection

alarm.

2. Set the Server IP Address to NP1000's alarm noti-

fication destination IP Address field. Also set the
port number 1818.

Select Scene Change
(cam)

8 Command alarm

i-Pro camera

1. Select ON for i-Pro devices' Command alarm.
2. Set the Server IP Address to i-Pro devices' alarm

notification destination IP Address field. Also set
the port number 1818.

Select Cmd Alm (cam)

9 Communication

Error (between cam-
era and recorder)

DVR (except RT416)

1. Set the Port number 1818 for Panasonic alarm.
2. Set the Server IP Address to Panasonic alarm

destination IP Address field.

Select Comm Err (cam)

10 Intruder detection

i-Pro encoder

See the NT314 Network Operating Instructions.

Select Intruder (cam)

11 Object detection

i-Pro encoder

See the NT314 Network Operating Instructions.

Select Object dct.
(cam)

12 Capacity Warning

DVR (except RT416)

1. Set the Port number 1818 for Panasonic alarm.
2. Set the Server IP Address to Panasonic alarm

destination IP Address field.

Select Capacity Warn
(dvr)

13 RAID Down

DVR (except RT416, ND200) 1. Set the Port number 1818 for Panasonic alarm.

2. Set the Server IP Address to Panasonic alarm

destination IP Address field.

Select RAID Down
(dvr)

14 Thermal Error

DVR (except RT416)

1. Set the Port number 1818 for Panasonic alarm.
2. Set the Server IP Address to Panasonic alarm

destination IP Address field.

Select Therm Err (dvr)