ADIC 4000 User Manual
Page 56

5-16
Operation and Maintenance
62-0162-01
Using cloth swabs, cotton swabs, cleaning agents, or
unapproved cleaning cartridges will void your warranty.
Use only an approved cleaning cartridge.
Table 5-6
Using the Cleaning Tape
If . . .
It means . . .
You should . . .
While using a data
cartridge, the
Use
Cleaning Tape
LED
illuminates
and the front
panel LCD displays:
and:
The drive head needs
cleaning or the tape is
bad
Use the cleaning cartridge.
Load the cleaning
cartridge according to
Loading the Data Cartridge
on page 5-12.
When cleaning is
complete, the beeper will
sound alerting you to
remove the cleaning
cartridge. Remove the
cleaning cartridge from the
drive according to
Removing the Data Cartridge
on page 5-14
While using a data
cartridge, the
Use
Cleaning Tape
LED
begins to blink and the
front panel LCD
displays:
and
The data cartridge may
be damaged
Back up the data from this
cartridge onto another
cartridge, it may be
damaged. A damaged
cartridge may cause
unnecessary use of the
cleaning cartridge.
Use Cleaning Tape
LED
still illuminates after you
clean the drive head.
Your data cartridge may
be causing the problem
Try another data cartridge.
Use Cleaning Tape
LED
illuminates after you
load the cleaning
cartridge
Cleaning has not been
accomplished and the
cleaning cartridge has no
remaining cycles
available.
Replace the cleaning
cartridge.
Caution