Section vii, Manual reset, Burner hi-limit instructions – American Dryer Corp. AD/ML-310 User Manual
Page 46: Manual reset burner hi-limit instructions

46
American Dryer Corp.
113217 - 5
SECTION VII
MANUAL RESET BURNER HI-LIMIT INSTRUCTIONS
This dryer was manufactured with a manual reset burner hi-limit thermostat, which is monitored by the Phase 7 computer.
If the burner hi-limit is open prior to the start of the drying cycle, the dryer will start momentarily and then shut down, the
Phase 7 computer will display “burner HIGH LIMIT fault” with an audio indication.
If the burner hi-limit opens during a drying cycle, the Phase 7 computer will also display the same error code described
above, along with an audio indication. If the drum temperature is above 100° F (38° C), the dryer will continue to run
with no heat for 3 minutes or until the drum temperature has dropped below 100° F (38° C). The clear/stop button on the
Phase 7 keyboard (touch pad) must be pressed to clear the error condition. The open burner hi-limit must be reset
“manually” prior to the start of the next cycle.
WARNING: Discontinue power to dryer before attempting to reset hi-limit.