beautypg.com

Gas – rear exhaust, Steam / gas – side exhaust – American Dryer Corp. AD/ML-310 User Manual

Page 28

background image

28

American Dryer Corp.

113217 - 5

2. Electrical Service Specifications

6/26/08

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT:

NOTES: A.

B.


C.

208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.

When fuses are used they must be dual element, time delay, current

limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value,
by applying either local and/or National Electrical Codes to listed appliance
amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY.
For others, calculate/verify correct breaker size according to appliance
amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

CIRCUIT

BREAKER

60 Hz

50 Hz

GAS – REAR EXHAUST

208

3/4

61.2

90

230

3

67.4

90

240

3

56.5

90

380

3/4

36.6

35.0

60

400

3/4

33.9

60

416

3/4

33.2

50

460

3

29.1

50

480

3

29.6

50

575

3

23.2

40

STEAM / GAS – SIDE EXHAUST

208

3/4

94.0

125

230

3

108.8

150

240

3

85.3

110

380

3/4

50.4

80

400

3/4

51.0

80

416

3/4

48.6

70

460

3

44.8

70

480

3

43.4

70

575

3

38.0

60