Gas – rear exhaust, Steam / gas – side exhaust – American Dryer Corp. AD/ML-310 User Manual
Page 28

28
American Dryer Corp.
113217 - 5
2. Electrical Service Specifications
6/26/08
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT:
NOTES: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value,
by applying either local and/or National Electrical Codes to listed appliance
amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY.
For others, calculate/verify correct breaker size according to appliance
amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
GAS – REAR EXHAUST
208
3ш
3/4
61.2
—
90
230
3ш
3
—
67.4
90
240
3ш
3
56.5
—
90
380
3ш
3/4
36.6
35.0
60
400
3ш
3/4
—
33.9
60
416
3ш
3/4
—
33.2
50
460
3ш
3
29.1
—
50
480
3ш
3
29.6
—
50
575
3ш
3
23.2
—
40
STEAM / GAS – SIDE EXHAUST
208
3ш
3/4
94.0
—
125
230
3ш
3
—
108.8
150
240
3ш
3
85.3
—
110
380
3ш
3/4
—
50.4
80
400
3ш
3/4
—
51.0
80
416
3ш
3/4
—
48.6
70
460
3ш
3
44.8
—
70
480
3ш
3
43.4
—
70
575
3ш
3
38.0
—
60