beautypg.com

Preoperational test, I. preoperational test – American Dryer Corp. AD/ML-310 User Manual

Page 36

background image

36

American Dryer Corp.

113217 - 5

I. PREOPERATIONAL TEST

ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be
performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal
location (installation) conditions.

1. Turn on electric power to the dryer.

2. Make sure the loading doors are closed and the lint drawer is closed.

3. Press in “green” power button and it will illuminate.

4. Microprocessor controller (computer) system operational test – to start the dryer:

a. Display will read “READY”.

b. Press “D” (preprogrammed) cycle key on the keyboard (touch pad).

5. The dryer will then start (i.e., blower, basket [tumbler], and heat).

6. The light emitting diode (L.E.D.) display will read MANUAL DRYING CYCLE D, 00:00 MIN REMAIN.

NOTE: Press the “UP ARROW” to view the basket (tumbler) temperature at any time.

NOTE: The dryer can be stopped at any time by pressing the “STOP/CLEAR”

O

key. If the temperature

is above the Cool Down set point when the “STOP/CLEAR”

O

key is pressed, the dryer will go into a

Cool Down Cycle. If the “STOP/CLEAR”

O

key is pressed again at this point the cycle that was in

progress will be canceled and returned to the “READY” state. If the temperature is below the Cool
Down set point, the cycle that was in progress will be canceled, and go into Wrinkle Guard Cycle.

7. When the programmed drying time has expired, the Phase 7 non-coin microprocessor controller (computer) will

proceed into the Cool Down Cycle (Mode).

8. Once the Cool Down Cycle begins at the end of the heat cycle, the L.E.D. display will read COOL DOWN TEMP

___/___ MINUTE REMAINING. At the end of the heat cycle, the dryer will shut off the heat and continue the fan
and basket (tumbler) until the Cool Down time, or temperature is reached.

9. Once the Cool Down Cycle is completed the Phase 7 non-coin microprocessor controller (computer) will proceed

into the Wrinkle Guard Cycle. The Audio Alert tone will sound prior to the start of the Wrinkle Guard Cycle. The
L.E.D. display will read “WRINKLE GUARD”. The times are fixed at 2 minutes OFF, 2 minutes ON for a
maximum time of 99 minutes. These times are not programmable. During the ON time, the blower (fan) and the
basket (tumbler) will start to rotate (without heat for 2 minutes). The Phase 7 non-coin microprocessor controller
(computer) will repeat this process until the Maximum Wrinkle Guard On Time has expired (99 minutes). The
L.E.D. display will then read “CYCLE DONE” and lockout the dryer functions until the doors are opened. It will
then return to “READY”.

NOTE: Mechanical functions of the dryer are not allowed during the ON time. The blower (fan) must

be OFF to perform mechanical functions. However the “STOP/CLEAR”

O

key may be pressed at

any time to end the Wrinkle Guard Cycle. Mechanical functions of the dryer is allowed during the
OFF time.