beautypg.com

B. location requirements, Tilt clearance allowance – American Dryer Corp. AD/ML-310 User Manual

Page 18

background image

18

American Dryer Corp.

113217 - 5

B. LOCATION REQUIREMENTS

The tilt model dryer requires 18-inches (45.72 cm) on the right side of the dryer for ease of service. The requirement for
the left side clearance on a 1 door dryer is 18-inches (45.72 cm) and for a 2 door dryer 36-inches (91.44 cm) is required
due to the side exhaust. The rear of the dryer requires a 36-inch (91.44 cm) clearance for ease of service. Refer to the
chart below for ceiling height requirements for each of the tilting dryer models.

The dryer must be leveled for proper operation. If shimming is required, place 11-inch x 10-inch (27.94 cm x 25.4 cm)
metal shims under the base feet. The dryer must be lagged to the floor.

1. The dryer must be installed with a proper exhaust duct connection to the outside.

2. The dryer must be installed with provisions for adequate combustion and make-up air supply.

Shaded areas are stated in metric equivalents

WARNING: Dryer should be located where a minimum length of exhaust duct will be necessary.

TILT CLEARANCE ALLOWANCE

Dryer Style

Ceiling Height Requirement

Gas

138-inches

350.52 cm

Steam

141-inches

358.14 cm