beautypg.com

K. shutdown instructions, K. shut down instructions – American Dryer Corp. AD/ML-310 User Manual

Page 39

background image

113217 - 5

www.amdry.com

39

9. Rotate the basket (tumbler/drum) by hand to be sure it moves freely.

10. Check bolts, nuts, screws, terminals, and fittings for security.

11. Check to ensure air supply (80 psi [5.51 bar]) is connected to the dryer.

12. STEAM MODELS – Check to ensure ALL steam shutoff valves are open.

K. SHUT DOWN INSTRUCTIONS

If the dryer is to be shut down (taken out of service) for a period of time, the following must be performed:

1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.

2. Discontinue the heat supply:

a. GAS MODELS – discontinue the gas supply.

1) SHUT OFF external gas supply shutoff valve.

2) SHUT OFF internal gas supply shutoff valve located in the gas valve burner area.

b. STEAM MODELS – discontinue steam supply.

1) SHUT OFF external (location furnished) shutoff valve.

2) SHUT OFF internal steam valves in the supply lines and the return lines.