Diagnostics – parking light flash table – Autostart CT-5460TW User Manual
Page 16
P. 16
User Guide
Diagnostics – Parking Light Flash Table
Flashes
Description
1
x Doors locked, Alarm and Starter Kill armed.
x End of Run Time.
x
TRUNK
button pressed
x Start signal received by the System.
x Cold Weather Mode cancelled.
2
x Doors unlocked, alarm and starter Kill disarmed.
x Run time cancelled.
x Exit remote valet.
x Exit ignition valet
x Remote start attempt cancelled by remote.
3
x Entering cold weather mode.
x Entering remote valet.
x Entering ignition valet
x Entering and exiting Ready Mode
x Entering estended run time
4
x +12 V where detected on the brake line and cranking was cancelled.
x Entering tach-programming mode
5
x New transmitter programmed.
x Tach programmed.
6
x A remote start was attempted while a tach or a vacuum signal was detected before
cranking.
8
x Unit reset: occurs when the unit is reset to the factory defaults.
10
x The hood switch line went to ground during cranking or run time.
1 – pause – 2
x There was an attempt to start the vehicle while the system was in valet mode.
2 – pause – 2
x There was an attempt to start the vehicle while the system was in home valet mode.
4 – pause – 3
x When the vehicle is running: +12 V detected on the Brake Line.
10 – pause – 3
x When the vehicle is running: the Hood Pin-switch went to ground.
ON solid
x Cold weather mode: the Brake Pedal is being held down.
ON 2 sec.
x The Hood is up and the Hood Switch line went to ground. This is step one of the
Programming Centre procedure.
ON 3 sec.
x First press of the
START/STOP
button under Safe Start.
ON 4 sec.
x Locking or unlocking a door (with Door pulses configured to 4 sec.)
ON 25 sec.
x The hood pin-switch has been pressed twice: the unit went into step 1 of the
programming centre procedure, and no transmitter activity was detected for 20
seconds.
x Or the unit went into step 1 of the transmitter programming procedure and no activity
was detected for a few seconds. The unit has exited the transmitter programming
procedure.
Irregular
x If the unit gives irregular signals (1 to 10 flashes followed by a pause, followed by
further flashes), the system is playing back start failure codes. This occurs when the
hood pin-switch is pressed three times.
Constant
flashes
up to 30 sec.
x Panic mode triggered with
LOCK
button, if programmed in passive arming.
Constant
flashes
up to 60 sec.
x
Panic mode triggered with
LOCK
button, if in passive mode.
x Panic mode triggered with
LOCK
and
UNLOCK
button, in active mode.
x
ON solid when alarm is triggered.
x
Alarm condition generated by an
intrusion, by panic mode.