background image

INSTALL POP-UP DRAIN

INSTALL BLACK GASKET

3

2

Install BLACK CONE GASKET (1) onto DRAIN BODY (2)
from below.

Note: The flat side of the BLACK CONE GASKET (1) must
face down.

4

Drop DRAIN BODY (4) through sink drain
hole. Make sure WHITE FOAM GASKET (5)
is under flange of DRAIN BODY (4).

Fig.

B.

Note: No plumber’s putty or caulk is required.

The CABLE ATTACHMENT POINT (6) must
face towards the rear of the SINK.

Fig.

B.

Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from
under DRAIN POP-UP (3).

Fig.

A.

2

REAR OF

SINK

4

5

6

3

1

SINK

DRAIN

HOLE

FLAT SIDE OF GASKET

MUST FACE DOWN

1

2

Fig.

A.

2

1

FLAT SIDE OF

GRAY LOCKNUT

MUST FACE UP

INSTALL GRAY LOCKNUT

5

Install GRAY LOCKNUT (1) onto DRAIN
BODY (2) from below SINK. Fig. A.

Note: The flat side of the GRAY LOCKNUT (1)
must face up.

Tighten firmly by hand. No tools are required.
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. B.

POP-UP KNOB (1) must be fully down.

POP-UP KNOB

Fig.

A.

Fig.

B.

3

WHITE FOAM

GASKET

NOT VISIBLE

DRAIN

FLANGE

Fig.

B.

1

M 9 6 8 4 2 2 R e v . 1 . 2

DOWN

2