Acer 2430 User Manual
Page 34
Chapter 1
29
Temperature Range( C)
Operating
Storage (shipping)
0 to 50
-20 to 60
0 to 50
-20 to 60
0 to 50
-25 to 60
AC Adapter
Item
Specification
Vendor & model name
LITE-ON - 65W, PA-1650-02 QY
Input Requirements
Maximum input current (A,
@90Vac, full load)
1.5 A @ 110Vac
1.0 A @ 240Vac
Nominal frequency (Hz)
50-60
Frequency variation range (Hz)
47-63
Input voltage range (Vrms)
90-265
Inrush current
Shall not be less than 220Amps (cold start) when AC input is 100V 60Hz and
DC output is +19V 3.42A
Shall not be less than 220Amps (cold start) when AC input is 240V 50Hz and
DC output is +19V 3.42A
Efficiency
It should provide an efficiency of 85% (typ. 88%) minimum, when measured at
maximum nominal voltage at 19.0V
Output Ratings (CV mode)
DC output voltage
19V
Noise + Ripple
380mV
Load
Voltage Nom. (V) Capacitance Nom. Material Type
25.0 10/1.0 TAN/CERAMIC
Output Ratings (CC mode)
DC output voltage
19V +/-0.95 for CV mode
Constant current mode
3.6 +0.60A/-0.3A
Dynamic Output Characteristics
Turn-on delay time
5 sec (@ 115Vac)
Hold up time
5ms (@115Vac, Full load)
Over Voltage Protection (OVP)
29V
Short circuit protection
5.0A max can be protected and output can be shorted without damage
Electrostatic discharge (ESD)
+/-15KV (at air discharge)
+/-8KV (at contact discharge)
Dielectric Withstand Voltage
Primary to secondary
2150Vac
Leakage current
100uA
Regulatory Requirements
Safety Requirements:
1.The power supply must comply with the following national standards: UL,
CSA, CCC, BSM, PCBC< CE, FIMKO, DEMKO, NEMKO, SIMKO, TUV
2. Dielectric Strength-primary to secondary: 2150 VDC for 1sec.
3. Insulation Resistance- primary to secondary: 30 Meg. ohms Min., 500VDC
4. Ground Leakage Current- the power supply ground leakage current shall be
less than 100uA.
LCD 15.0”
Item
Specification
°