beautypg.com

6 checking the drives for data consistency, Checking the drives for data consistency -24, Using the check consistency – Asus DSEB-D16 User Manual

Page 134

background image

5-24

Chapter 5: RAID configuration

5.2.6

Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected logical

drive. The utility can automatically detect and/or detect and correct any differences

in data redundancy depending on the selected option in the Objects > Adapter

menu.

The Check Consistency command is available only for logical drives included

in a RAID 1 set.

Using the Check Consistency

To check data consistency using the Check Consistency command:
1. From the Management Menu, select Check Consistency, then press

.

2. The screen displays the available RAID set(s) and prompts you to select the

logical drive to check. Press the to select the logical drive from

the Logical Drive selection, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

CC Of VD(s)

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

SPACE-(De)Select, F10-Check Consistency

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

Select VD

Logical Drive(s) Configured

LD RAID Size #Stripes StripSz Status

0 10 154494MB 4 64 KB ONLINE

Logical Drives

Loical Drive 0

This manual is related to the following products: