Performance and alarms – ADC Network Unit User Manual
Page 25
Chapter 3: Provisioning
3-7
User and Privilege Settings
Purpose:
Defines users to the system.
Command: [SECURE privilege]
SET USER
CLEAR USER
User name and passwords are specified as 1 to 15 alphanumeric characters.
Status Command: [SECURE privileges]
GET USERS
Performance and Alarms
Configure Alarm Thresholds
Purpose:
Configures the OAM alarm threshold and windows for CRC, Errored Symbol Period, Errored Frame Event, Errored
Frame Period, and Errored Frame Seconds Summary events.
Command: [RW,SECURE privilege]
SET [
•
geted.
•
•
IEEE 802.3ah. For convenience, MINIMUM and MAXIMUM are keywords that can be substituted for
to set the values to the minimum and maximum values specified in IEEE 802.3ah.
• [WINDOW
Example: SET FRAME PERIOD EVENT THRESHOLD 1
Example: SET SUBSCRIBER CRC EVENT THRESHOLD MINIMUM WINDOW MAXIMUM
Status Command: [all privileges]
GET [NETWORK|SUBSCRIBER] EVENT THRESHOLD
GET [NETWORK|SUBSCRIBER] ALARM STATUS