Spektrum SPMAR6310 User Manual
Page 11
![background image](/manuals/429160/11/background.png)
EN
11
Problem
Possible Cause
Solution
Aircraft does
not function
after connecting
flight battery and
aircraft smells
burnt
User may have acciden-
tally plugged the flight
battery in with the wrong
polarity
Replace AR600C board and
ensure the RED polarity
marks are facing the same
direction when connecting
the flight battery to the
AR6310 board
The system will
not connect
Your transmitter and
receiver are too close
together. They should be
8 to 12 feet apart
Move transmitter 8 to 12 feet
from receiver
You are around metal
objects
Move to an area with less
metal
Model selected is not the
model bound to
Check model selected and
ensure you are bound to that
model
Your transmitter was
accidentally put into bind
mode and is not bound to
your receiver anymore
Rebind your transmitter and
receiver
Receiver quits
responding
during operation
Inadequate battery voltage
Charge batteries. Spektrum
receivers require at least
3.5V to operate. An
inadequate power supply can
allow voltage to momentarily
drop below 3.5V and cause
the receiver to brownout and
reconnect
Loose or damaged wires
or connectors between
battery and receiver
Check the wires and conne-
ction between battery and
receiver. Repair or replace
wires and/or connectors
Receiver loses
its bind
Transmitter stand or tray
could be depressing the
bind button
Remove from stand and
rebind
Bind button pressed befo-
re transmitter turned on
Rebind your system fo-
llowing binding instructions
Receiver blinking
at landing
System turned on and
connected, then receiver
turned off without turning
off transmitter
Turn off transmitter when
receiver is turned off