beautypg.com

Exponential – Spektrum SPM2121 DX2S User Manual

Page 13

background image

13

SPEKTRUM DX2S USER GUIDE

EN

exponenTIal

Exponential is used to affect the response rate of the

steering, throttle and/or brake. On the DX2S, positive

Exponential will reduce steering sensitivity around neutral

making it easier to drive at high speeds in a straight line

while still allowing for maximum turning radius. While

sensitivity with positive Exponential is reduced around

neutral, it increases the sensitivity near the end of travel.

The DX2S’ Exponential function (Expo for short) allows

independent Expo values in each direction on the

steering and throttle channels.

To aCCess The exponenTIal funCTIon

From the list screen use the Rolling Selector to highlight

the Exponential function.

Press the Rolling Selector to enter the Exponential

function. The Expo screen will be displayed as shown on

this page.

Rotate the Rolling Selector and highlight the values next

to the desired channel you wish to adjust.

ST = Steering

TH = Throttle and brake

Press the Rolling Selector to enter the highlighted

channel’s Expo function.

Rotating the Rolling Selector will now adjust both the

upper and lower values simultaneously. If you desire to

adjust the left or right Expo values independently, move

the corresponding channel’s wheel or throttle, and that

value alone will be highlighted (e.g. turning the steering

wheel to the right will highlight the right value only and

subsequent adjustment will affect the right travel only).

Note: Positive and negative Expo values are

available. A positive Expo value results in the

center being less sensitive (desirable most of

the time) while a negative value increases the

sensitivity around center (normally not used).

Note: The DX2S features “sticky gooey.”

When the corresponding channel is moved

to the desired position and released, as

illustrated above, the value on that side

remains highlighted. Moving the channel

in the opposite direction will then highlight

the opposite value direction. This allows

convenient independent exponential

adjustments without having to hold the wheel

or trigger in the desired position. To highlight

both values again after moving the control

in one direction, simply press the Rolling

Selector twice with the control centered and

both values will be highlighted.

To return to the Main screen press and hold the Rolling

Selector for more than three seconds.

This manual is related to the following products: