The Data Reset function allows you to reset all the programming in the selected model (1 or

2) to the factory default settings. Before using the Data Reset function, it’s important to enter

the Model Select function and check to make sure the current model number indicated (1 or

2) is the model to which you want to reset to the factory default settings. The Model Select

function is described in detail on page 16.

Accessing the Data Reset Function

To access the Data Reset function, follow the steps below:

1. Press the

SCROLL and CHANNEL keys at the same time and hold.

2. Turn on the transmitter power switch to enter the System Mode.
3. Press the

SCROLL key until CLR appears on the screen.

4. Press the

INCREASE and DECREASE keys at the same time to reset the data. To

confirm that the selected model’s programming has been reset, a beep will sound and

the model number selected (1 or 2) will stop flashing.

5. To exit the System Mode, either turn the transmitter power switch off or press the

SCROLL and CHANNEL keys at the same time.

The DX2.0 features a selectable RF mode. N is the standard RF mode. FR is the France RF

mode and should only be selected if the transmitter is used in France.

Accessing the RF mode Function

To access the RF Mode function, follow the steps below:

1. Press the

SCROLL and CHANNEL keys at the same time and hold.

2. Turn on the transmitter power switch to enter the System Mode.
3. Press the

SCROLL key until RF appears on the screen.

4. Press the

INCREASE and DECREASE keys to select the desired RF mode.

5. To exit the System Mode, either turn the transmitter power switch off or press the

SCROLL and CHANNEL keys at the same time.

Data Reset

(System Mode)

RF Mode

clr

1

Indicates model to be reset

To enter the Function Mode, turn on the transmitter and then press the

SCROLL key. The

display will change to show the first function listed on the Function Mode flow chart as

shown below. Press the

SCROLL key to scroll down through the functions one by one, as

shown in the flow chart. Once the desired function has been reached, use the

CHANNEL key

to select the appropriate channel (if applicable). To adjust the values of the function, simply

press the

INCREASE (+) or DECREASE (-) keys until the desired value is displayed on the

screen. To exit function mode, press the

SCROLL and CHANNEL keys at the same time.

The next time you enter Function mode, you will be returned to the last function accessed.

Accessing

the Function

Mode

Channel
Key

I00

TRIM

stS

st

I00

E P A

tH

Endpoint
Adjustment
(page 20)

Channel
Key

st

REV • NORM

Channel
Key

0

E P A

TRIM

tHS

0

st

REV • NORM

SB-TRM

Sub-Trim
(page 21)

Servo
Reversing
(page 22)

R/B

L/F

RF