Installation, Final check lists – Blodgett BC-20G User Manual
Page 15

11
Installation
Final Check Lists
WaRnInG!!
Final check list must be performed by a quali-
fied installer only.
ELECTRICaL COnTROL COMPaRTMEnT
• Voltage to appliance matches rating plate
PLUMBInG FInaL CHECK
• Incoming water pressure within appliance specifica-
tion.
• Atmospheric vented drain in place.
• Water solenoid properly bracketed and not leaking.
• Water feed lines intact without leaks.
• Ensure proper clearance.
• Delime system has been primed.
• Optional Spray Hose connected properly. Connect
the optional spray hose to the fill solenoid as shown.
Cold Water
Supply
Hose and Spray
Option
To Oven Fill
Manifold
Figure 4
OVEn OPERaTIOnaL TESTS
NOTE: Checks to be made by customer or authorized
service agent.
Cool down Mode
• Check that the fan runs with the door open.
Steam Mode
Place in STEAM mode and set thermostat to 212ºF
(100ºC). Verify the following:
• Heat demand lamp is on.
• Heat demand lamp shuts off at approximately 212ºF
(100ºC).
• Set timer for 1 minute. Be sure the buzzer sounds
when the time expires.
• Unit produces steam, window fogs, door seal does
not leak.
Combi Mode
Place in COMBI mode, set thermostat to 350ºF (177ºC)
and verify:
• Heat demand lamp is on (manual and digital controls
only).
• Oven is heating.
• Heat demand lamp shuts off at 350ºF (177ºC) and
oven maintains 350ºF (177ºC) (manual and digital
controls only).
• Fan shuts off with door open.
Hot air Mode
Place in HOT AIR mode and set thermostat to 400ºF
(204ºC) and verify:
• Heat demand lamp is on.
• Oven is heating.
• Heat demand lamp shuts off at 400ºF (204ºC) and
oven maintains 400ºF (204ºC).
• Fan shuts off with door open.
Steam On demand Mode
Place in Hot Air mode. Set Steam On Demand for 1 min-
ute. Press the Steam On Demand button and verify:
• Steam demand lamp is on.
• Steam demand lamp shuts off after approximately 1
minute.
Fan Speed
• Ensure both fan speeds work.