14

If the LINK OK LED does not light, there is no signal continuity.

1. Check that the attached Data Terminal Equipment (DTE) is ON.

2. Check that the Link signal has not been disabled at the other network

device.

If these checks do not identify the problem, it may indicate that the hub or
device connected to the port is faulty.

Verifying Collision LED

The COLLISION LED will blink when an SQE or collision occurs. Occasional
collisions are normal in Ethernet networks. A COLLISION LED that remains
on may indicate that a specific port is experiencing excessive traffic problems.

Continuous blinking of the COLLISION LED may also indicate excessive frame
collisions on a segment. This may be caused by an overloaded segment, a faulty
cable or connection.