background image

Removable Power Supply and Fan

14

Switch

The following table describes how LEDs on the switch report operations and
faults with installed PSUs and FOMs.

LED

State

Description

PSU 1
and
PSU 2

Green

The PSU is installed and supplying power to the switch.
The voltage output is within specification.

Red

One of the following:
• The PSU is installed in the switch, and a fan has

failed or the PSU has exceeded its recommended
temperature threshold of 70ºC (158º F).

• A FOM is installed in the switch and a fan has failed.

The x900-12XT/S and the SwitchBlade x908
switches do not support FOMs.

• The bay is empty. Applies to AT-8948, AT-9924Ts,

x900-24XT, x900-24XT-N, x900-24XS, and
AT-10408XP switches which require a FOM when
only one PSU is installed.

• Dual PSUs are installed, but the PSU is not

receiving power.

Off

A FOM is installed and operating at an acceptable
speed. For AT-9924T, x900-48FE, x900-48FE-N, x900-
48FS, and SwitchBlade x908 switches, a blanking plate
is installed.