Checking leds – Allied Telesis Removable Power Supply and Fan User Manual
Page 14

Installation Guide
13
Checking LEDs
LEDs on PSUs, fans, and the front panels of switches indicate the operational
status of the devices. After you have installed a PSU or fan and have powered on
the switch, check the LEDs to verify operation by using the following tables.
PWR01
PWR02
The following table describes LEDs on the PWR01 and PWR02 power supply
units.
PWR05
The following table describes LEDs on the PWR05 power supply unit.
FAN01
The following table describes LEDs on the FAN01 fan-only module.
FAN03
The following table describes LEDs on the FAN03 chassis fan.
LED
State
Description
FAULT
Red
The temperature on the PSU has exceeded the limit of
75º C (167º F), or the fan failed.
PWR
GOOD
Green
A PSU is installed in the switch and is delivering power.
LED
State
Description
~
Green
AC input voltage is within 90-264VAC, 47-63Hz.
Off
AC input voltage is outside the acceptable range.
Green
DC output voltage is within 12V +/- 10%.
Off
DC output voltage is outside the acceptable range.
Red
A fault has occurred. There is either a fan failure, or the
temperature has exceeded its limit of 70ºC (158ºF).
Off
No fault conditions detected.
LED
State
Description
FAULT
Red
The fan has failed.
LED
State
Description
FAN
STATUS
Red
The fan has failed.