Selecting a Site for the Chassis
The site chosen for the unit should meet the following requirements:
The power outlet should be close to the chassis and be easily
accessible.
The site should allow for easy access to the media converter module
slots on the front panel and to the power supply connectors on the
back panel.
There should be unrestricted air flow around the vents of the chassis.
There should not be any objects placed on top of the chassis.
The site should be a moisture-free environment.
The site should be a dust-free environment.
The power sources for a chassis that has two power supplies should
be located on different circuits to protect the unit from a power circuit
failure.
Dedicated power circuits or power conditioners should be used to
provide reliable electrical power to the network device.
If you are installing the chassis on a table, the table should be level
and secure.
The site should not expose the media converter chassis or the twisted
pair cables to sources of electrical noise, such as radios, electric
motors, transmitters, broadband amplifiers, power lines, and
fluorescent fixtures.