beautypg.com

Twisted pair and fiber optic cable specifications, Twisted pair cable specifications – Allied Telesis x600-48Ts/XP User Manual

Page 44

background image

Chapter 3: Cabling the Network Ports

44

Twisted Pair and Fiber Optic Cable Specifications

Twisted Pair

Cable

Specifications

Table 9 lists the cabling specifications for the 10/100/1000Base-T twisted
pair ports.

Note

The auto-MDI/MDI-X feature on the twisted pair ports automatically
configures the MDI/MDI-X setting when a link is established with an
end node. Available when a port is at the default setting of Auto-
Negotiation, this feature allows you to use a straight-through twisted
pair cable when connecting any type of network device to a port.

Disabling Auto-Negotiation on a port and setting the speed and
duplex mode manually also disables the auto-MDI/MDI-X feature. A
port where Auto-Negotiation has been disabled defaults to MDI-X.
Disabling Auto-Negotiation may require manually configuring a
port’s MDI/MDI-X setting or using a crossover cable.

Table 9. Twisted Pair Cabling and Distances

Speed

Cable Type

Maximum

Operating

Distance

10 Mbps

Standard TIA/EIA 568-B-compliant
Category 3 or better shielded or
unshielded cabling with 100 ohm
impedance and a frequency of 16
MHz.

100 m (328 ft)

100 Mbps

Standard TIA/EIA 568-A-compliant
Category 5 or TIA/EIA 568-B-
compliant Enhanced Category 5 (Cat
5e) shielded or unshielded cabling
with 100 ohm impedance and a
frequency of 100 MHz.

100 m (328 ft)

1000 Mbps

Standard TIA/EIA 568-A-compliant
Category 5 or TIA/EIA 568-B-
compliant Enhanced Category 5 (Cat
5e) shielded or unshielded cabling
with 100 ohm impedance and a
frequency of 100 MHz.

100 m (328 ft)

This manual is related to the following products: